TIF8800
|
| Combustible Gas Detectors |
| Product Weight: 2.75 lbs. |
| Dimensions: 11.562x7.625x3.125 inch |

|
- Instantaneous response
- Ultimate sensitivity as low as 1ppm (gasoline)
- Used in almost any situation where combustible gasses, vapor or residues need to be found
- Detects dangerous explosive gases
- Automatic warm up
- Applications include: Gas lines and pipes, aids in identifying Heat Exchanger leaks and hazardous living/working environments (Note: not an effective Carbon Monoxide detector - see TIF8500A
- Adjustable sensitivity
- Audible 'Geiger counter" type signal
These detectors are MSHA approved and UL Classified. The unique flexible 15" stainless probe allows you to access hard to reach places. All feature automatic warm-up and are ideal for a tremendous range of uses and are invaluable for safety in many applications.
| Partial List of Detectable Compounds |
| Compound |
Min. detectable concentration |
Compound |
Min. detectable concentration |
| Acetylene |
50 ppm |
Methyl Chloride |
5 ppm |
| Iso-Butane (R600a) |
500 ppm |
Hydrogen Sulfide |
5 ppm |
| Methane |
500 ppm |
Acetone |
50 ppm |
| Ethane (R170) |
500 ppm |
Methanol |
50 ppm |
| Propane (R290) |
500 ppm |
Ammonia (R717) |
20 ppm |
| Ethylene |
500 ppm |
Gasoline |
1 ppm |
| Hydrogen |
500 ppm |
Chlorine |
1 ppm |
| Methyl Ether |
500 ppm |
|
|
| Vinyl Chloride |
5 ppm |
|
|
Image Files Low Quality High Quality |
Document Files English Operating Instructions English Other
|
|
|
|
|
|
|
|
|
|